AI is sizzling, capturing headlines, investments, and customers. It additionally runs sizzling, actually: The data centers working artificial intelligence (AI) fashions use giant quantities of electrical energy and generate huge warmth. To maintain servers from overheating, many amenities depend on cooling methods that use water.
AI information facilities’ water use is available in two types. Past the water that cools the servers, information facilities not directly contribute to water use by the electricity generation wanted to energy their operations. That oblique use usually makes up 80 percent or more of the general water use.
Decreasing AI’s water footprint means tackling two very totally different points—what occurs inside the information middle partitions, and what occurs past them on the power grid.
Direct Water Use: Native and Typically Traumatic
Simply as human our bodies cool themselves by sweating, information facilities are sometimes cooled by water evaporation—a course of that dissipates warmth and leads to water being misplaced to the ambiance, and thus being counted as “consumed.” In lots of circumstances, the water is drawn from the identical municipal methods that provide houses and companies.
Whereas most main tech corporations now disclose their direct water use, not all data centers follow suit, making the general image unclear. In current studies, corporations have estimated that between 45 percent and 60 percent of withdrawn water is consumed.
In accordance with a current report by Lawrence Berkeley National Laboratory, the 2023 direct water consumption by information facilities in america—residence to about 40 percent of the world’s data centers—is estimated at roughly 17.5 billion gallons. Assuming a 50 p.c consumption ratio, meaning 35 billion gallons of water withdrawal, or about 0.3 p.c of the total public water supply for the contiguous United States. The identical report initiatives that the U.S. information middle direct water consumption might double and even quadruple the 2023 degree by 2028.
On the nationwide degree, information facilities’ water use is comparatively modest. However in some areas the place information facilities are concentrated—and particularly in areas already going through shortages—the pressure on native water methods might be vital. Bloomberg Information studies that about two-thirds of U.S. information facilities constructed since 2022 are in high water-stress areas.
In Newton County, Georgia, some proposed information facilities have reportedly requested extra water per day than the entire county uses each day. Officers there now face powerful decisions: reject new initiatives, require different water-efficient cooling methods, put money into pricey infrastructure upgrades, or danger imposing water rationing on residents.
The largest stress will not be whole use, however timing. On sizzling days when residents and companies want water most, information middle water demand spikes too. In Arizona, an information middle’s month-to-month water utilization in the course of the summer time might be nearly twice its average level.
Oblique Water Use: Thirsty Electrical energy
The opposite a part of the equation is the electrical energy that powers information facilities. In lots of locations, electrical energy—whether or not for coaching AI models in information facilities or turning on a lightbulb in a house—is generated by fossil fuel-based power plants that require cooling water of their very own. The U.S. electric power sector withdraws about 11.6 gallons of water and consumes 1.2 gallons for each kilowatt-hour of electrical energy produced, inserting it among the many nation’s largest water users. The water used to provide the electrical energy that powers information facilities is taken into account oblique water use.
The water utilized by energy crops is usually not potable and never drawn from municipal water methods. Nonetheless, it could possibly place stress on rivers, aquifers, and ecosystems—particularly in water-scarce areas.
For many U.S. information facilities, this oblique use is considerably larger than direct onsite water use. One paper estimated that in 2023, utilizing GPT-3 to generate a single textual content output of 150 to 300 phrases consumed a total of 16.9 milliliters of water in a median U.S. information middle—2.2 ml for onsite cooling and 14.7 ml for electrical energy technology. It’s possible that effectivity good points in later fashions have diminished these numbers, however oblique water use nonetheless predominates.
The way to Reduce Knowledge Facilities’ Water Influence
Not like electrical energy, data center cooling methods are a design alternative. Evaporative cooling is low-cost and environment friendly, however it could possibly burden native provides throughout summer time heatwaves, when water is most wanted and least out there. To handle that peak demand, information facilities can construct onsite water storage or set up thermal energy storage. Upgrading water infrastructure—comparable to increasing distribution or fixing leaks—can even assist native methods higher deal with demand spikes.
Alternate options to evaporative cooling embrace air-based and liquid-immersion cooling, utilizing recycled water to chop potable water use, and waste heat reuse to scale back cooling demand. Some superior designs recycle cooling water in a closed-loop, so no water is consumed; these “zero-water” designs remove the necessity to faucet into native drinking water provides. Nonetheless, many of those designs increase electrical energy demand, which in flip can improve oblique water use. Water-cooled information facilities consume about 10 percent less energy than air-cooled information facilities.
In immersion cooling methods, servers are submerged in a fluid that carries warmth away with out evaporating water. Jason Alden/Bloomberg/Getty Pictures
In water-stressed areas, the precedence ought to be low- to zero-water cooling methods to scale back direct use, whereas investing so as to add renewables to the native grids to curb oblique water use and reduce carbon emissions from larger electrical energy demand. In wetter areas with carbon-intensive grids, precedence ought to be given to decreasing energy use to decrease the general water consumption, even when meaning continued use of evaporative cooling with its larger onsite water consumption.
The truth of the intertwined water and electrical energy methods forces information middle operators to navigate powerful trade-offs between international local weather objectives and native water wants. These decisions usually aren’t easy, however till renewables dominate electrical energy grids, they might be unavoidable.
The views expressed on this article are these of the authors and don’t essentially mirror the views of their employers or affiliated establishments.